Hobart 157 Calibration of power rinse tank pressure transmitter AI6 failed.
Severidad Media 157
🔍
Diagnóstico Inmediato
Calibration of power rinse tank pressure transmitter AI6 failed.
Power rinse tank pressure sensor PRS3 (AI6)
⚙️
Causa Técnica
| Componente | Problema detectado | Cómo verificarlo |
|---|---|---|
| Power rinse tank pressure sensor PRS3 (AI6) | Calibration of power rinse tank pressure transmitter AI6 failed. |
🛠️
Solución — Pasos de Reparación
- 1 Paso 1 Ensure drain lever was open long enough
- 2 Paso 2 Check stuck drain lever
- 3 Paso 3 Check for clog in drain line