Hobart 090 Minimum wash tank temp did not reach 153 °F within 20 minutes.
Severidad Media 090
🔍
Diagnóstico Inmediato
Minimum wash tank temp did not reach 153 °F within 20 minutes.
Wash tank heater, thermistor
⚙️
Causa Técnica
| Componente | Problema detectado | Cómo verificarlo |
|---|---|---|
| Wash tank heater, thermistor | Minimum wash tank temp did not reach 153 °F within 20 minutes. |
🛠️
Solución — Pasos de Reparación
- 1 Paso 1 Check wash temp thermistor - QTM1 - for damage and tightness
- 2 Paso 2 Check tank heater (amps on each leg), wiring and contactor
- 3 Paso 3 Check high limits
- 4 Paso 4 Look for damaged wires in control box
- 5 Paso 5 Check incoming water temperature
- 6 Paso 6 Ensure thermal paste between thermistor and tank